ISO 4406 target cleanliness & filtration calculator
Set particle and moisture targets from machine type and criticality, then model filtration with a Schroeder mass-balance (ISO 16889 β-ratios). Forward mode predicts achievable ISO code; reverse recommends a filter; ΔP estimates clean-element pressure drop; Suggest picks a filter grade and housing.
Beginning targets for particles (ISO 4406) and water (ppm). Answer all six for a criticality-adjusted ISO + dryness target, see the Des-Case component guideline and a new-oil fill target (~2 codes cleaner), then optionally push the ISO into Filter Recommendation below.
Des-Case guideline table (starting points)
| Machine / configuration | Target ISO |
|---|
Adjust up/down for criticality and risk appetite. New oil should typically be kept ~2 codes cleaner than the in-service target.
Filter Selection
Operating Conditions (Ingression)
These factors estimate contaminant ingression into the system. Worse conditions mean the filter must work harder and the achievable cleanliness will plateau higher.Pick a standard, then turn the dials, type a code or enter particle counts. The equivalent in the other standards is shown underneath. Uses the published tables only (ISO 4406:2021, SAE AS4059G, NAS 1638); it does not change the filtration model above.
Turn a dial: drag or swipe it, scroll over it, use the ▲ ▼ buttons or the arrow keys. Small numbers under each value are the upper count limit per mL.
Turn the dial to pick a class. The small line is the 5–15 µm limit per 100 mL.
Or enter NAS 1638 counts per 100 mL (5 size bands)
Or enter particle counts (cumulative, µm(c))
More sizes (optional): ≥21, ≥38, ≥70 µm(c) for full AS4059 and NAS 1638 classes
NAS 1638 is inactive for new designs but is still widely specified, for example in offshore subsea specifications. Conversions between NAS 1638, ISO 4406 and AS4059 are approximate because the size bands differ.
Editions & sources
- ISO 4406:2021 (4th edition, Jan 2021; reviewed and confirmed by ISO on 29 Jun 2026, so it is still current). Scale numbers 0–28 and >28 are the same as in the 2017 edition. The 2021 change: particle contamination monitors (PCMs) calibrated to ISO 21018-3/-4 may now be used to report the code, as well as APCs calibrated to ISO 11171.
- SAE AS4059G (revised Nov 2022; replaces Rev F of 2013, reaffirmed 2020). Table 1 (differential, B–F) uses the same limits as NAS 1638. Table 2 (cumulative, A–F, classes 000–12) is reported as “cpc”. ISO 11218:2017 (aerospace) adopts AS4059F.
- NAS 1638 (AIA): inactive for new designs after 30 May 2001 (see AS4059). The latest issue says it is not for use with automatic particle counters.
- Microscope counts (-/x/y codes) follow ISO 4407, revised in Dec 2025 (ISO 4407:2025).
- ISO ↔ NAS read-across (approximate): MP Filtri and Invicta charts (NAS N ≈ ISO N+11/N+9/N+6) and the Chevron chart (N+10/N+9/N+6). The estimate uses the ≥6 and ≥14 µm(c) numbers, where the charts agree. The worse size sets the class.
ISO 4406:2021 Table 1 · SAE AS4059G Tables 1–2 (MP Filtri reprint, 2026) · NAS 1638 · cross-checked against Parker, Chevron, Hy-Pro and Invicta
The tables are reprints. Check the purchased standard before using a value for acceptance testing.
Show full table
ISO 4406:2021 — allocation of scale numbers
Particles per mL. Each range runs from “more than” up to and including the upper value. Tap a number in the ≥4, ≥6 or ≥14 column to set that dial.
Show full table
NAS 1638 — cleanliness classes 00–12
Maximum particles per 100 mL, differential (within each band). Sizes are microscope sizes (longest dimension). The class is the highest band class. Tap a class to select it.
Show full table
SAE AS4059G — contamination classes