System & Maintenance · DWG LS-034

Oil cooler & heat exchanger sizing

Find out how much heat your oil cooler has to get rid of and which coolers on the market can do it. Answer three questions; the answer appears below. Preview, preliminary selection only: confirm with the maker’s sizing software before purchase.

Maker data (AKG, Bowman, Emmegi, Parker, HYDAC catalogs) and published methodsLast reviewed

Source: AKG oil cooler catalogs (akgcoolers.com) · Parker SWO / PWO water-oil cooler catalogs (PDF) · Alfa Laval brazed plate heat exchanger instruction manual (PDF)

Preview. Each match is labelled: Maker rating, Read from maker chart, or Calculated from published geometry (±20%, Martin / VDI Heat Atlas correlation validated against two makers). Linear ETD scaling, the single-point flow window and the pump-loss fraction are rules of thumb. Confirm every selection with the maker’s sizing software before purchase.

1 · Your system
Fills in a 40 gpm hydraulic unit with ISO VG 46 oil, cooled by 85 °F water.
What are you cooling?

Sets a typical oil grade. You can change it below.

What cools it?
Your numbers

Pump flow, or the return-line flow that goes through the cooler.

The hottest oil temperature you want to allow. Hydraulics: often 120–140 °F.

same unit

Usually 10–20 °F cooler than the oil going in. Don’t know? Use “More options”.

The ISO VG number on the drum or in the manual (ISO 3448 viscosity grade).

same unit

Use the warmest water, or the hottest summer air, you expect.

More options: other ways to get the heat load, result units
How do you want to work out the heat load?

From the maker, a heat survey or a previous cooler.

%

Rule of thumb: AKG suggests 25% of input power for most hydraulic power units (40 hp unit = 10 hp heat load). Use a measured value if you have one.

3 · Can I swap to a brazed plate cooler?

For a cooler that is shell-and-tube today. Brazed plates are small and cheap but less forgiving.

Seawater and salty water attack the copper brazing.

Opens the matching water-test questions below.

Most copper-brazed units are rated about 30 bar (435 psi).

°C

A brazed plate can only be cleaned with chemicals, never rodded.

More questions: water test, strainer, cold start, mounting
mg/L

From a water analysis.

mg/L
°C

Chloride limits get tighter as water gets hotter.

Cold, thick oil can over-pressure a plate cooler.

°C
Full checklist with sources
Words, method & sources
Glossary
  • Heat load: the heat the cooler must remove, in hp, kW or BTU/h.
  • Temperature gap (ETD, entering temperature difference): oil temperature going in minus water (or air) temperature going in. The bigger the gap, the smaller the cooler.
  • Extra capacity (margin): how much more the cooler can remove than you need, at your flow and temperatures.
  • ISO VG: oil viscosity grade per ISO 3448; the number is the oil thickness in cSt at 40 °C.
  • Brazed plate (BPHE): stainless plates brazed together with copper; compact, cannot be opened or rodded.
  • Shell-and-tube: oil around a bundle of water tubes inside a shell; tubes can be rodded out.
  • Rule of thumb: engineering practice, not a maker limit.
How it works: formulas, fits, correlations
  • Heat load Q = ρ · V · cp · (Tin − Tout), with oil properties at the mean oil temperature. Viscosity comes from the ISO VG grade (ISO 3448, kinematic viscosity at 40 °C) through the ASTM D341 (Walther) chart equation, assuming a viscosity index of about 100. Density, specific heat and conductivity use the Cragoe petroleum-oil correlations (US NBS Misc. Pub. 97). The pump-power option is a rule of thumb (AKG: about 25% of input power).
  • ETD = oil inlet temperature − coolant (water or ambient air) inlet temperature. Cooler capacity is taken as proportional to ETD at a given oil flow, the selection method AKG and Emmegi publish; for other makers it is a rule of thumb.
  • Maker rating: a number printed in the maker’s table (Bowman, Emmegi, Parker SWO). Single-point ratings are used only from 70% to 100% of the rated oil flow (rule of thumb) and scaled by ETD.
  • Read from maker chart: AKG curves were digitized from the vector PDF charts and fitted (q = Q / (A + B·Q), median fit error 0.4%); Parker PWO curves were read by eye from chart images (about ±3% of full scale). Flows outside the printed curve are excluded. On the AKG A-series chart the printed y-axis labels (about 29.0 pt per doubling) do not line up with the plotted gridlines (27.8 pt per doubling); A-series values use the midpoint of the two readings, capped at 6% above the label reading, and are shown as ±7%.
  • Calculated from published geometry (±20%): HYDAC HEX S brazed plate units, from the plate dimensions and plate pitch in the HYDAC catalog, using the Martin (1996) chevron-plate correlation (VDI Heat Atlas N6), ε-NTU counterflow, ISO VG 46, oil in 60 °C, water in 20 °C, water flow half the oil flow. Assumed (not published): 60° chevron angle, area enlargement 1.17, 0.4 mm plates, port bore from thread size. Without any fitting, the same method predicted AKG/P ratings with 6.9% mean error (90% within 13%) and Parker PWO ratings with 12.5% mean error (90% within 20%) above an oil Reynolds number of 20; lower flows are left out.
  • Not included: Bosch Rexroth AB32-09 (table values not yet verified against the PDF), oil-side pressure drop, altitude and fan-speed corrections, and fouling allowances.
  • Swap check limits are quoted from the makers’ water-quality and installation documents listed below; items marked rule of thumb are engineering practice, not a maker limit.

Sources

Manufacturer websites (for sizing confirmation and local distributors)

Catalogs and references